External reservoir providing a dead-ended fluid blanket to the quench connection.
Application Notes
- Typically used when a dead-ended atmospheric quench is needed.
- Can be used to prevent or remove any ice formation on the atmospheric side of the seal of a pump operating with a fluid below 32°F [0°C].
- Continuous quench supply such as steam is not needed.